Interface hook-up data sheet for Gina Krog

Norsok Standard Z-015

General information

Plant type: Fast innretning

Electrical

Power * Volt [V] Frequency [Hz] Phase Current [A] Neutral Loaded [Yes/No] System Earth ** Short Circuit Level Min [kA] Short Circuit Level Max [kA] Distribution Protection Fuse [A] Distribution Protection Earth Fault [mA] Connection Platform (Description / Type) Connection Temporary Equipment (Description / Type) Area (Module Number / Room Number)
Main 690 3ph +PE 60 125 R 125 GHG 515 4405 R3001, SOCKET OUTLET, Exde IIC T6 GHG 515 7405 R0001 Ex. Plug, Exde IIC T6 10 pc. W200, W300
Main 690 3ph +PE 60 63 R 63 GHG 514 4405 R3001, SOCKET OUTLET, Exde IIC T6 GHG 514 7405 R0001 Ex. Plug, Exde IIC T6 13 pc. E600, P250, P300, P350, P400, P600, W100, W200, W300
Main 690 3ph +PE 60 32 R 32 GHG 512 4405 R3001, SOCKET OUTLET, Exde IIC T6 GHG 512 7405 R0001 Ex. Plug, Exde IIC T6 7 pc. Q300, W200, W300
Main 400 3ph +N +PE 60 125 S 125 GHG 515 4506 R3001, SOCKET OUTLET, Exde IIC T6 GHG 515 7506 R0001 Ex. Plug, Exde IIC T6 Main; 7 pc. E600, P250, P300, P350, P400, P600, W200 Emg; 0 pc.
Main 400 3ph +N +PE 60 63 S 63 GHG 514 4506 R3001, SOCKET OUTLET, Exde IIC T6 GHG 514 7506 R0001 Ex. Plug, Exde IIC T6 Main; 27 pc. E600, P100, P200, P250, P300, P350, P400, P600, Q100, Q300, Q400, W100, W200 Emg; 0 pc.
Main 230 1ph +N +PE 60 16 S 16 GHG 511 4306 R3001, SOCKET OUTLET, Exde IIC T6 GHG 511 7306 R0001, Ex. Plug, Exde IIC T6 Main; 54 pc. E500, E600, P100, P200, P250, P300, P350, P400, P500, P600, Q100, Q250, Q300, Q400, W100, W200, W300 Emg; 0 pc.
UPS 230 2ph +PE 60 16 I 16 GHG 511 4306 R3001, SOCKET OUTLET, Exde IIC T6 GHG 511 7306 R0001, Ex. Plug, Exde IIC T6 10 pc. Q300, W100, W200, W300
Emg 690 3ph +PE 60 125 R 125 GHG 515 4405 R3001, SOCKET OUTLET, Exde IIC T6 GHG 515 7405 R0001 Ex. Plug, Exde IIC T6 0 pc.
Emg 690 3ph +PE 60 63 R 63 GHG 514 4405 R3001, SOCKET OUTLET, Exde IIC T6 GHG 514 7405 R0001 Ex. Plug, Exde IIC T6 5 pc. W200, W300
Emg 690 3ph +PE 60 32 R 32 GHG 512 4405 R3001, SOCKET OUTLET, Exde IIC T6 GHG 512 7405 R0001 Ex. Plug, Exde IIC T6 7 pc. Q300, W200, W300

*
Main - Main Power,
Emg - Emergency Power,
Ess - Essential Power,
UPS - UPS Power

**
S = Solidly (direkte jordet),
I = Isolated (isolert)
R = Resistance (resistansjordet)

Instrument

Function Signal type Connection platform (Description / Type) Connection temporary equipment (Description / Type) Area (Module Number / Room Number)
Loss Of Pressure NO- kontakt (kontakt=alarm) 2K? i parallel med kontakt / 910? in series med kontakt Socket: GHG 591 4201 R0002 6h Pin 7,8,9 Plug: GHG 591 2201 R0002 6h Pin 7,8,9 W100 : 70JBE0071 W200 : 70JBE0073, 0074, 0075, 0087, 0088, 0089, 0090 W300 : 70JBE0076, 0077, 0078, 0091, 0092, 0093, 0094, 0095, 0096 E600 : 70JBE0086
Fire NO- kontakt (kontakt=alarm) 2K? i parallel med kontakt / 910? in series med kontakt Socket: GHG 591 4201 R0002 6h Pin 1,2,3 Plug: GHG 591 2201 R0002 6h Pin 1,2,3 W100 : 70JBE0071 W200 : 70JBE0073, 0074, 0075, 0087, 0088, 0089, 0090 W300 : 70JBE0076, 0077, 0078, 0091, 0092, 0093, 0094, 0095, 0096 E600 : 70JBE0086
Gas NO- kontakt (kontakt=alarm) 2K? i parallel med kontakt / 910? in series med kontakt Socket: GHG 591 4201 R0002 6h Pin 4,5,6 Plug: GHG 591 2201 R0002 6h Pin 4,5,6 W100 : 70JBE0071 W200 : 70JBE0073, 0074, 0075, 0087, 0088, 0089, 0090 W300 : 70JBE0076, 0077, 0078, 0091, 0092, 0093, 0094, 0095, 0096 E600 : 70JBE0086
Other NO- kontakt (kontakt=alarm) 2K? i parallel med kontakt / 910? in series med kontakt Socket: GHG 591 4201 R0002 6h Pin 10,11,12 Plug: GHG 591 2201 R0002 6h Pin 10,11,12 W100 : 70JBE0071 W200 : 70JBE0073, 0074, 0075, 0087, 0088, 0089, 0090 W300 : 70JBE0076, 0077, 0078, 0091, 0092, 0093, 0094, 0095, 0096 E600 : 70JBE0086
ESD Battery System NO- kontakt (kontakt=alarm) 2K? i parallel med kontakt / 910? in series med kontakt Socket: GHG 591 4201 R0002 6h Pin 13, 14 Plug: GHG 591 2201 R0002 6h Pin 13, 14 W100 : 70JBE0071 W200 : 70JBE0073, 0074, 0075, 0087, 0088, 0089, 0090 W300 : 70JBE0076, 0077, 0078, 0091, 0092, 0093, 0094, 0095, 0096 E600 : 70JBE0086

Telecom

Function Signal type Connection platform (Description / Type) Connection temporary equipment (Description / Type) Area (Module Number / Room Number)
PA Audio, 100V line. Socket: STAHL 8570/11-404 (yellow) Plug: STAHL 8570/12-404 (yellow) W100, 2 units, W100-US-001 W200, 2 units, W200-US-001 W200, 4 units, US-W200-002-E W200, 4 units, US-W200-003-E W300, 4 units, US-W300-001-E W300, 4 units, US-W300-002-E W300, 4 units, US-W300-003-E E600, 2 units, E600-US-001
Telephone Audio Socket: STAHL 8570/11-410 (green) Plug: STAHL 8570/12-410-S (green) W100, 1 unit, W100-US-001 W200, 1 unit, W200-US-001 W200, 2 units, US-W200-002-E W200, 2 units, US-W200-003-E W300, 2 units, US-W300-001-E W300, 2 units, US-W300-002-E W300, 2 units, US-W300-003-E E600, 1 unit, E600-US-001
Data (Fibre) LC fiber connector LC fiber connector W100, 86RBC0003Y, W100-US-001 W200, 86RBC0004Y, W200-US-001 W200, 86RBC0006Y, US-W200-002-E W200, 86RBC0008Y, US-W200-003-E W300, 86RBC0012Y, US-W300-001-E W300, 86RBC0018Y, US-W300-002-E W300, 86RBC0014Y, US-W300-003-E E600, 86RBC0017Y, E600-US-001

Utilities

Function
Pressure [bar]
Amount/Flow [max capacity] Connection - type Connection - diameter Connection - material Area (Module Number / Room Number)
Plant Air 7 bar, Dew Point -40deg Cel NA NA Brass All modules
Instrument Air NA
Sprinkler
Seawater
Freshwater
Drain
Other

Lifting capacity offshore cranes

Crain 1 meter * 2 meter * 3 meter *
1218-73MA001 2 Fall hovedløft: Max 34 tonn på 45,0m radius Max 34 tonn på 42,5m radius Max 34 tonn på 40,0m radius
1218-73MA001 3 Fall hovedløft: Max 50 tonn på 35,0m radius Max 50 tonn på 35,0m radius Max 50 tonn på 35,0m radius
1218-73MA001 1 Fall hovedløft: Max 17 tonn på 57,5m radius Max 17 tonn på 55,0m radius Max 14,9 tonn på 55,0m radius

* Significant waveheight [max. load / max. radius]

Additional information

General kommentar for B&G:
Relene som er inne i brannsentralen i containeren må være NDE, dette fordi at når container mister spenning (singel gas) så skal ikke alarmer aktiveres.


Eksempel på framføring av instrumentsignal i container. Alternative løsninger aksepteres, men signalkontakter og motstander skal være tilkoplet pinnene i støpselet slik som vist 
NB !! Alle 10 motstandene skal inn selv om signalet ikke er i bruk. Dette for å unngå signalfeil-alarm i kontrollrom.


 