Interface hook-up data sheet for Gullfaks C
Norsok Standard Z-015
General information
Plant type: Fast innretning
Electrical
| Power * | Volt [V] | Frequency [Hz] | Phase Current [A] | Neutral Loaded [Yes/No] | System Earth ** | Short Circuit Level Min [kA] | Short Circuit Level Max [kA] | Distribution Protection Fuse [A] | Distribution Protection Earth Fault [mA] | Connection Platform (Description / Type) | Connection Temporary Equipment (Description / Type) | Area (Module Number / Room Number) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Main | 440 3p+e | 60 | 63 | S | 63 | Socket: STAHL 8579/31-507 (black) 7h | Plug: STAHL 8579/22-507 (black) 7h | Welding socket outlets all over the plattform | ||||
| Main | 230 2p+e | 60 | 16 | S | 16 | Socket: STAHL 8570/11-306 (blue) 6h | Plug: STAHL 8570/12-306 (blue) 6h | Socket outlets all over the platform | ||||
| Emg | 440 3p+e | 60 | 63 | S | 63 | Socket: STAHL 8579/31-507 (black) 7h | Plug: STAHL 8579/22-507 (black) 7h | Four sokcet outlets for the wire-line unit in the M16/17 area | ||||
| Emg | 440 3p+e | 60 | 125 | S | 125 | Socket: GHG 515 4507 V0 7h | Plug: GHG 515 7507 V0 7h | M16 BOP three socket outlets M17 BOP four socket outlets D31T North and South | ||||
| Main | 440 3p+e | 60 | 125 | S | 125 | Socket: GHG 515 4507 V0 7h | Plug: GHG 515 7507 V0 7h | C11 one socket outlet, C14 one socket outlet, M13M North one socket outlet, M16D North one socket outlet, M19D one socket outlet M19T one socket outlet M24M South one socket outlet, D11T one socket outlet, D21D North and South D31T North and South |
*
Main - Main Power,
Emg - Emergency Power,
Ess - Essential Power,
UPS -
UPS Power
**
S = Solidly (direkte jordet),
I = Isolated (isolert)
R = Resistance
(resistansjordet)
Instrument
| Function | Signal type | Connection platform (Description / Type) | Connection temporary equipment (Description / Type) | Area (Module Number / Room Number) |
|---|---|---|---|---|
| Loss Of Pressure | DI - NO (Digital Input- Normaly open) | Socket outlet: CEAG GHG 511 4906 R0001 6h KU, pin 7, 8 | Plug CEAG GHG 591 2201 R0002 6h pin 7, 8 | L119, M13M, M21S, M21N, M24N, M16BOP, M17BOP, M19D, M19T, D21S, D21N, D31S, D31N |
| Fire | DI - NO (Digital Input- Normaly open) | Socket outlet: CEAG GHG 511 4906 R0001 6h KU, pin 1, 2 | Plug CEAG GHG 591 2201 R0002 6h pin 1, 2 | L119, M13M, M21S, M21N, M24N, M16BOP, M17BOP, M19D, M19T, D21S, D21N, D31S, D31N |
| Gas | DI - NO (Digital Input- Normaly open) | Socket outlet: CEAG GHG 511 4906 R0001 6h KU, pin 4, 5 | Plug CEAG GHG 591 2201 R0002 6h pin 4, 5 | L119, M13M, M21S, M21N, M24N, M16BOP, M17BOP, M19D, M19T, D21S, D21N, D31S, D31N |
| Other | DI - NO (Digital Input- Normaly open) | Socket outlet: CEAG GHG 511 4906 R0001 6h KU, pin 10, 11 | Plug CEAG GHG 591 2201 R0002 6h pin 10, 11 | L119, M13M, M21S, M21N, M24N, M16BOP, M17BOP, M19D, M19T, D21S, D21N, D31S, D31N |
| ESD Battery System |
Telecom
| Function | Signal type | Connection platform (Description / Type) | Connection temporary equipment (Description / Type) | Area (Module Number / Room Number) |
|---|---|---|---|---|
| PA | STAHL 8570/11-404 4h (yellow) | STAHL 8570/12-404 4h (yellow) | D21S, D21N, M13MN, M16 BOP, M17 BOP, M19D, M19T | |
| Telephone | STAHL 8570/11-402 2h (green) | STAHL 8570/12-402 2h (green) | D21S, D21N, M13MN, M16 BOP, M17 BOP, M19D, M19T | |
| Network (Fiber) | MM fiber | Probeam Jr (see attached drawing) | Probeam Jr | D21S, D21N, D31T, M16/M17 BOP, M19D, M19T |
Utilities
| Function |
Pressure [bar]
|
Amount/Flow [max capacity] | Connection - type | Connection - diameter | Connection - material | Area (Module Number / Room Number) |
|---|---|---|---|---|---|---|
| Plant Air | ||||||
| Instrument Air | ||||||
| Sprinkler | ||||||
| Seawater | ||||||
| Freshwater | ||||||
| Drain | ||||||
| Other |
Lifting capacity offshore cranes
| Crain | 1 meter * | 2 meter * | 3 meter * |
|---|---|---|---|
| Kran 3 | 50 t./16 meter | 45 t./16 meter | 37 t./16 meter |
| Kran 4 | 30 t./23,5 meter | 28,5 t./23,5 meter | 23,5 t./23,5 meter |
| Kran 1 | 50 t./16 meter | 45 t./16 meter | 37 t./16 meter |
| Kran 2 | 39,5 t./19 meter | 33,5 t./19 meter | 27 t./19 meter |
* Significant waveheight [max. load / max. radius]
Comments
I TABELLEN VISES MAKS. LØFTEKAPASITET FOR LØFT MED STORBLOKK FRA FORSYNINGSSKIP (tonn) I FORHOLD TIL SIGNIFIKANT BØLGEHØYDE (meter).
Additional information
Eksempel på fremføring av instrumentsignal i kontainer GFC:
Kontainer skal alltid bestykkes med 4 stk 2K endemotstander og 4 kabelpar, selv om ikke kontainer har funksjonalitet for alle signaltyper.